ProofTimelineHeat

RippleXn Ltd · ProofTimeline Heat

Terms for equipment and records

These terms describe the five-node room and outdoor logging service from RippleXn Ltd, Huntingdon, Cambridgeshire, UK. The accepted written order identifies the equipment, service term, territory and final charges.

Equipment, quotations and dispatch

Four indoor and one outdoor node record numeric temperature and relative humidity. A five-indoor configuration needs a separate outdoor reference for an outdoor-adjusted index. An enquiry, waitlist place or budget estimate is not an order. We confirm the final VAT, delivery charges, terms and availability before acceptance. Pre-configured dispatch is within 10 working days of an accepted order. Postal packs use a return pouch. Follow the accepted return instructions.

Pilot and fleet

The evaluation is fixed at 30 days, with no rolling renewal. Trial reset access extends to 60 days. The pilot fee is credited toward a written fleet or partner rollout agreed within 60 days of the first on-site reading. On an outright fleet, the mobile and record-service pass runs for ten years from activation or 500 MB of data per node, whichever comes first. It includes unlimited property resets during the pass. Coverage and mobile network continuity affect service. The pass covers connectivity and record hosting. Batteries are consumables and separate from the service term.

Lawful placement and actual heating

Obtain the owner’s express authority and agree all required occupant access and notice. Keep usual safe heating and ventilation. The supplied examples assume the stated schedule. Never ask occupants to experience unsafe cold to collect a curve. Use the same positions and note the weather when comparing periods. The commissioning account holder chooses positions and labels, protects access, records permission and decides who may receive its reports.

Recorded conditions and limits

This record covers air temperature and humidity at the measuring points. It is not a SEAI BER or DEAP assessment, UK EPC or RdSAP/HEM assessment, EU national certificate or French DPE, ISO 9869 heat-flux U-value measurement, blower-door airtightness test or SCSI/RICS building survey.

Readings and indoor–outdoor differences apply to the stated weather window. Heat transfer through the fabric, infiltration, ventilation, room size, thermal mass, sunlight, doors, heating and occupants can all affect slopes. The node readings alone do not identify causes, quantify fuel savings, determine heat-pump readiness, establish a legal threshold or certify a property. An air dew point is calculated from temperature and relative humidity. A surface margin requires a separate paired surface temperature. Poor contact or unsafe placement may invalidate a comparison. Target air accuracy is ±0.2°C and ±2 percentage points RH, pending finished-unit confirmation.

Record hosting, lawful use and disputes

Our role is supply of hardware and automated storage of timestamped records. We have not inspected the property. Keep names, accusations and fabricated inputs out of readings and room labels. We do not provide expert evidence or voluntary case advocacy. We comply with lawful compulsory orders. For business customers, reasonable costs caused by unlawful placement or misuse, compulsory extraction, and contractual liability limits are governed by the incorporated ProofTimeline terms for records and disputes.

Where lawful and reasonable, compulsory work in a business customer’s dispute may be charged at up to £200 or €240 per hour plus documented necessary external costs. The commercial liability cap is the fees paid for the affected unit and included service in the 12 months before the claim, subject to the exceptions in the linked terms. England and Wales law governs. Nothing in these terms affects mandatory consumer rights or limits liability that cannot lawfully be limited.

Working with a report

A sealed report includes recorded readings and flags missing intervals. You can verify its file fingerprint at ProofTimeline verification. The public sample files are fictional and identified as examples. A verified file does not certify physical mounting, causation, calibration, building condition, valuation or legal status.

Back to packs and pricing